Property InformationOtemon Tower / ENEOS Building

Located in the "Daimaruyu" area, comprised of the Tokyo neighborhoods of Otemachi, Marunouchi, and Yurakucho, Japan's preeminent business district. Provides the convenience of direct access to Otemachi Station, which is served by five subway lines. Contributing also to initiatives to reduce environmental impacts and improve the local environment.

Access

  • Directly connected to Otemachi Sta. on the Tozai Line, Chiyoda Line, Hanzomon Line, and Marunouchi Line; the Toei Mita Line
  • 8 min. on foot from Tokyo Sta. on the JR lines (accessible via underground passageway)

Features and facilities

  • Directly connected to underground shopping area
    Directly connected to underground shopping area
  • Emergency power generator that can operate for 72 hours
    Emergency power generator that can operate for 72 hours
  • Security gate present or can be installed
    Security gate present or can be installed
  • Restaurants
    Restaurants
  • Convenience store
    Convenience store

Property overview

Location 1-1-2, Otemachi, Chiyoda-ku, Tokyo
Nearest station Directly connected to Otemachi Sta. on the Tozai Line, Chiyoda Line, Hanzomon Line, and Marunouchi Line; the Toei Mita Line
8 min. on foot from Tokyo Sta. on the JR lines (accessible via underground passageway)
Completion Nov. 2015
Gross floor area 107,571.33 m²* (32,540.33 tsubo)
  • *Including portions owned by co-owners
Scale 22 floors above ground, 5 floors below ground
Structure Steel-frame structure (partly steel-frame ferroconcrete structure)
Uses Offices, stores, and parking lot
Design and supervision Mitsubishi Jisho Design Inc.
Construction KAJIMA CORPORATION, NIPPO CORPORATION
Certifications and awards DBJ Green Building Certification ★★★★★
ABINC Certification
Parking lot 195 cars (monthly and hourly rental)
Other facilities Fitness center

Overview of rental rooms and facilities

Power receiving system 22 kV 3-circuit receiving method
Emergency power generator In the event of a power outage, the building’s generators can supply 13 VA/m² of power (approx. 72 hours)
Ceiling height 2,850 mm
Raised floor 150 mm
Floor load 500 kg/m² (heavy duty zone: 1,000 kg/m²)
Outlet power supply capacity 75 VA/m²
Air-conditioning unit Each floor is divided into eight zones and uses a variable air volume (VAV) system
Security Security personnel on duty 24 hours a day
Security gate present